Products 1-19 of 19
Show
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VJ -
The 30 degree elbow allows installation of a gas heater at a 30 or 60 degree angle inside the structure. The angle is not adjustable. This stainless steel vent pipe fitting features a patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV venting applications. What is UL 1738? In short, it is a...
Free Shipping
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: 4610175 -
This 5" vent kit is for Sterling TF100, TF125, TF150, TF175, TF200, TF250, XF100, XF125, XF150, XF175, XF200, XF250, GF150, and GF250 models. (Not for use with Sterling XF Concentric Vent Kits)Each vent system comes complete with everything needed to vent the Sterling TF, GF, and XF series heaters. These stainless steel, gas tight vent systems are approved by Sterling for horizontal venting applications for these gas heaters. These are the most durable, longest lasting, and lowest maintenance...
Free Shipping
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: 465110 -
For Sterling models GG30, GG45, GG60, GG75, GG90, GG105, & GG120Each vent system comes complete with everything needed to vent a Sterling GG heater. These stainless steel, gas tight 4" vent systems are approved by Sterling for horizontal installation in residential and commercial applications for GG model heaters. These are the most durable, longest lasting, and lowest maintenance vent systems available for these gas heaters. All vent systems are for horizontal venting of all Sterling GG gas...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: 465010 -
Vent Size Compatible Gas Heaters 3 inch Modine Hot Dawg - HD30, HD45, HD60, & HD75 4 inch Modine Hot Dawg - HD100 & HD125 Mr. Heater / Big Maxx - MHU50, MHU80, MHU125 Reznor - UDX & UDZ (up to 125K BTU) Dayton - Low profile unit heaters up to 120K BTU These universal heater exhaust kits come complete with everything needed to vent a gas heater up to 3' (additional pipe and/or a drip tee may be required for some units). These 3' stainless steel, gas tight, category 3 vent...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VL -
The stainless steel heater vent pipe is available in several different sizes and lengths. If you do not find the exact length needed, adjustable length pipes are also available. Vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV venting applications. What is...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VC -
The 90 degree elbow allows installation of a gas heater at a 90 degree angle inside the structure. It can also be used if vertical runs are needed as well. The angle is not adjustable. This stainless steel vent pipe fitting features a patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VD -
The 45 degree elbow allows installation of a gas heater at a 45 degree angle inside the structure. The angle is not adjustable. This stainless steel vent pipe fitting features a patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV venting applications. What is UL 1738? In short, it is a US...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VE -
Adjustable vent pipes can slide in and out of a standard vent pipe giving you an adjustable length. The amount of adjustment available depends on the length of the pipe it is connected to. Requires at least 4” overlap for a secure connection. Vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VF -
The heater adapter has a silicone gasket and locking band on one end to connect to the category 3 piping and a universal screw mount on the opposite end for connecting to the heater. Heater adapters are required to secure the category 3 venting to a gas unit heater. Adapters fit most standard gas unit heaters including: Modine, Sterling, Mr. Heater, Reznor, ADP, and Dayton brands (other heater brands may need some minor modifications for assembly). 3" and 4" universeal adapters include 3 oz....
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VG -
This unique wall thimble has a built-in 18" section of adjustable pipe which goes to the inside of your structure giving you a lot of flexibility when running the vent pipe to your heater. The pipe is also sealed to the thimble so there is no air leakage to worry about. This thimble is for walls 4 1/4" to 8 1/2" thick (extensions are available for thicker walls). The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VH -
Firestop flashings are recommended for venting through combustible walls less than 4" thick. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV venting applications. What is UL 1738? In short, it is a US standard for gas venting...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VI -
Vent tees are designed to be used with the condensate caps in vertical or horizontal venting systems. A cap is placed in the lowest part of the Tee and collects any condensate that forms in the venting. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VK -
The storm collar is used to create a seal around the vent pipe and the firestop flashing or wall pass through. No collar is needed with the adjustable wall thimble. All pipe and fittings are UL1738 approved for category II, III and IV venting applications. What is UL 1738? In short, it is a US standard for gas venting systems required in category 3 applications. Category 3 refers to positive vent pressure which is created by exhaust blowers in unit heaters. These vent systems must be...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: 4651335 -
The wall pass through is for 5" pipe and walls 4 1/4" to 8 1/2" thick (extensions are available for thicker walls). A storm collar is recommended to seal around it and the vent pipe. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VM -
Used for standard and high-wind through-the-wall terminations. Comes with built-in screens to keep birds out. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV venting applications. What is UL 1738? In short, it is a US standard for...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VA -
Condensate caps are designed to be used with the Tee fittings in vertical or horizontal venting systems. It is placed in the lowest port of the Tee and collects any condensate that forms in the venting. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VB -
The drip tee is used to drain condensation if you do not have a 1/4" for foot downward slope in your horizontal vent line. Drip tee are for horizontal installations only. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV venting...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: 4651330 -
The universal drain is used to drain condensation if you do not have a 1/4" for foot downward slope in your horizontal vent line or in vertical venting applications also. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. All pipes and components are engineered with smooth clean welds located 90° from mechanical locking bands. All pipe and fittings are UL1738 approved for category II, III and IV venting...
Availability: In Stock - Usually ships in 1 to 2 days.
Item #: VN -
The wall thimble extension is used to add 6” of length to Wall Pass Through and Wall Thimble for thicker walls. What is UL 1738? In short, it is a US standard for gas venting systems required in category 3 applications. Category 3 refers to positive vent pressure which is created by exhaust blowers in unit heaters. These vent systems must be constructed of AL29-4C® stainless steel, contain gaskets for sealing, and have a built in mechanical locking band among other requirements. All category 3...